BM 100 Biomaxima Qiasmed

BM 100

Fully automatic clinical chemistry random access analyzer.

  • Throughput - up to 150 tests/hour
  • Reaction cuvettes - 81 disposable reaction cuvettes
  • Wavelengths - 8 wavelengths in the range 340 to 670 nm
  • An independent arm for mixing of sample and reagents
  • Sample probe - with liquid level detection and collision protection
  • The volume of the reaction mixture- from 150 to 500 µl
  • The volume of dispensed sample - 2-50 µl
  • The volume of reagent dispensed - R1 - 150-300 l, R2 20-300 µl
  • Positions for reagents - 40 positions cooled to 4-12 °C
  • Positions for samples - 40 positions cooled to 4-12 °C
  • Calibration curves - linear and nonlinear, one -, two- and multipoint
  • Quality control - Levy-Jenningsa charts with Westgard rules, Twin Plot and checksum
  • Controlled - external PC running Windows XP / 7 with a laser printer
  • Connection to LIS - HL7 protocol
BM 200 Biomaxima Qiasmed

BM 200

Fully automatic clinical chemistry random access analyzer.

  • Throughput –up to 230 tests/hour (450 with ISE)
  • ISE module for Na, K, Cl, Li as option
  • Build in barcode reader
  • Reaction cuvettes - 81 disposable reaction cuvettes with an optical path of 5 mm
  • Wavelengths - 8 wavelengths in the range 340 to 670 nm
  • An independent arm for mixing of sample and reagents
  • Sample probe - with liquid level detection and collision protection
  • The volume of dispensed sample - 2-50 µl
  • The volume of reagent dispensed - R1 - 150-300 l, R2 20-300 µl
  • Positions for reagents – 40, bottles 20 and 30 ml, cooled to 4-12°C
  • Positions for samples – 40, tubes with diameter 12-14 mm and height 35-100 mm, and microcups, cooled to 4-12°C
  • Calibration curves - linear and nonlinear, one -, two- and multipoint
  • Quality control - Levy-Jenningsa charts with Westgard rules, Twin Plot and Checksum
  • Controlled - external PC running Windows XP / 7 with a laser printer
  • Connection to LIS - HL7 protocol
BM 500 Biomaxima Qiasmed

BM 500

Fully automatic clinical chemistry random access analyzer.

  • Throughput – up to 400 tests/hour (560 with ISE)
  • ISE module for Na, K, Cl as option
  • Build in barcode reader for samples and reagents
  • Reaction cuvettes – reusable 100 reaction cuvettes
  • 8 steps cuvettes washing system
  • Wavelengths - 12 wavelengths in the range 340 to 800 nm
  • Two arm for mixing of sample and reagents
  • Sample probe - with liquid level detection and collision protection and clot detector
  • The volume of dispensed sample - 2-45  µl
  • Up to 4 reagents in one reaction
  • The volume of reagent dispensed - R1 - 150-350  µl, R2 – R4 - 20-250  µl
  • Positions for reagents – 80 bottles 20, 30 ml and 70 ml, cooled to 2-10°C
  • Positions for samples – 100 tubes with diameter 12 - 14 mm height 35-100 mm, microcups
  • Connection to LIS - HL7 protocol